Flowtech Flowmeter

Product Details
Customization: Available
Accuracy: ±0.2-0.5%
Size: Dn15-2000

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
46
Year of Establishment
1995-04-10
  • Flowtech Flowmeter
  • Flowtech Flowmeter
  • Flowtech Flowmeter
Find Similar Products

Basic Info.

Model NO.
KF700VA
Sensor
Tube/Flange
Application
Environmental Protection
Type
Electromagnetic Flow Meter
Measuring Media
Liquid
Measuring Principle
Electrical Principles
Dn10-Dn2000
1/2inch-80inches
Transport Package
Cartons/Wooden Box
Specification
DN10-DN2000
Trademark
FLOWTECH
Origin
China
HS Code
902610000
Production Capacity
500PCS/Month

Product Description

Electromagnetic flowmeter
Conductivity mediums like acid, alkali, juice, milk, water, waste water, etc
Economic low cost digital flowmeters

KF700 electroomagnetic flowmeter is an inductive apparatus to measure the flow volume of electric medium in the tube. The flowmeter composes of sensor and converter, the flowmeter design is adopted of SCM built-in technology to realize digital inciting magnetism the SCM connects CAN bus-mastering in the electromagnetic flowmeter at the same to time. The electromagnetic flowmeter can not only be read straightly but also output 4-20mA current signal for purpose of memory, adjustment and control, the flowmeter is extensively used in industry technology and administration department such as chemical industry, environmental protection, metallurgy, medicine, paper making and water supply, etc.
Functional characteristics
1The structure of flowmeter is simple, function is reliable because there are no transmission parts, the working lifetime is long.
2 there are no block and cut-off parts, so the phenomenon of pressure loss and liquid block is not existed.
3 there is no mechanical inertia, fast response, excellent stability, it can be applied on automatic inspection adjustment and program process system.
4 the preciseness of measure is free of physical data influence of medium varieties, temperature, viscidity, density and pressure etc.
5 the different configurations of both PTFE or rubber lining and electrical poles Hc, Hb, 316L, TI etc can satisfy different medium requirements.
6 there are two models: Integration and separation
7 high definition LCD displayer

Technical data
Gauge preciseness: Pipe style 0.5 grade, 1.0 grade, insert style 2.5 grade
Measure medium: Two kinds of flowing substances: All of liquids and liquid-solids whose electric conductance ratio is less than 5US/CM
Flow speed range: 0.3-12m/s
Working pressure: 0.6-4.0MPa
Environmental temperature: 0-55C
Medium temperature: PTFE lining less than 150C, rubber lining less than 65C
Anit-explosion signal: Exd IIBT4
Electromagnetic interference: Less than 400A/m
Shell protection: Integration style: IP65, separation style: Sensor IP68, converter IP65
Output signal: 4-20mA, loading resistance 0-750Ω
Transmission output: RS485 or can bus-line
Electrical connection: M20*1.5 female thread, 10 cord hole
Electrical power voltage: DC18-36V, AC85-265V
Maximum power consumption: Less than 15W


In the normal industry application, it is better to set the measured medium speed as 2-4m/s, under the special situation, the minimum speed should be more than 0.2m/s and maxium speed less than 8m/s, if there are solid granules in liquid, the usual speed should be less than 3m/s for purpose to avoid the over-atrition between lining and electrical poles, for viscid liquid, the speed can choose as 2m/s, the fast flow speed makes for the automatic elimination of obstructive substance glued on poles, therefore improve the inspections preciseness.
Paratus selection    
DN Usual full range flow volume selection(m3/h) Integration  Partial installation
weights(KG)  weights (KG)
10 0.16,0.2,0.25,0.3,0.4,0.5,0.6,0.8,1.0,1.2,1.6,2.0,2.5 6 4
15 0.4,0.5,0.6,0.8,1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0 6 4
20 0.6,0.8,1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0 6 4
25 1.0,1.2,1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0 7 5
32 1.6,2.0,2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0 9 7
40 2.5,3.0,4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0 10 8
50 4.0,5.0,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,70 12 10
65 ,6.0,8.0,10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,80,100,120 17 15
80 10.0,12.0,14.0,16.0,20.0,25.0,30.0,40.0,50,60,80,100,120,160 17 15
100 16.0,20.0,25.0,30.0,40.0,50,60,80,100,120,160,200,250 22 20
125 25.0,30.0,40.0,50,60,80,100,120,160,200,250,300,400 24 22
150 40.0,50,60,80,100,120,160,200,250,300,400,500,600 35 33
200 60,80,100,120,160,200,250,300,400,500,600,800,1000 45 43
250 100,120,160,200,250,300,400,500,600,800,1000,1200;1600 84 82
300 120,160,200,250,300,400,500,600,800,1000,1200;1600,2000,2500 102 100
350 200,250,300,400,500,600,800,1000,1200;1600,2000,2500,3000 123 121
400 250,300,400,500,600,800,1000,1200;1600,2000,2500,3000,4000 147 145
450 300,400,500,600,800,1000,1200;1600,2000,2500,3000,4000,5000 212 210
500 400,500,600,800,1000,1200;1600,2000,2500,3000,4000,5000,6000 229 207
600 600,800,1000,1200;1600,2000,2500,3000,4000,5000,6000,10000 252 250
700 800,1000,1200;1600,2000,2500,3000,4000,5000,6000,10000,12000 352 350
800 1000,1200;1600,2000,2500,3000,4000,5000,6000,10000,12000,16000 462 460
900 1200;1600,2000,2500,3000,4000,5000,6000,8000,10000,12000,16000   550
1000 1600,2000,2500,3000,4000,5000,6000,8000,10000,12000,16000;20000   680

Flowtech Flowmeter
Flowtech Flowmeter
Flowtech Flowmeter


Flowtech Flowmeter

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier